ACTIVE DIFFERENTIAL PROBE 700 TO 7000 V, 70 TO 100 MHzThe TA042, TA043 and TA044 are active differential oscilloscope probes. They let you use a conventional earthed oscilloscope to measure signals that are not referenced to ground, including mains voltages. They can also be used to measure and observe the waveforms of three-phase supplies or the gate and control signals of semiconductor circuits. They are ideal for investigating motor speed controls, uninterruptible power supplies, switch mode power supplies and process controllers. |  |
|
 |
|
ACTIVE DIFF PROBE 1400 V, 100 MHz SPECIFICATIONDescription: 100 MHz 1400 V differential probe Attenuation: 100:1, 1000:1 Bandwidth: 100 MHz Rise Time: 3.5 ns Differential voltage range: 140 V DC + peak AC: 100 V RMS 70 V + peak AC: 70 V RMS Common mode range: 1400 V + peak AC: 1000 V RMS Input impedance: 4 MΩ/7 pF each side to ground Power requirements: 4 x AA cells (supplied) Safety rating: CAT III |
|
 |
|
 |
 |
|
ACTIVE DIFF PROBE 700 V, 100 MHz SPECIFICATIONDescription: 100 MHz 700 V differential probe Attenuation: 10:1, 100:1 Bandwidth: 100 MHz Rise Time: 3.5 ns Differential voltage range: 700 V + peak AC: 500 V RMS 1400 V + peak AC: 1000 V RMS Common mode range: 700 V + peak AC: 500 V RMS Input impedance: 4 MŁ/7 pF each side to ground Power requirements: 4 x AA cells (supplied) Safety rating: CAT III |
|
 |
|
 |
 |
|
ACTIVE DIFF PROBE 7000 V, 70 MHz SPECIFICATIONDescription: 70 MHz 7000 V differential probe Attenuation: 100:1, 1000:1 Bandwidth: 70 MHz Rise Time: 3.5 ns Differential voltage range: 700 V + peak AC: 500 V RMS 7000 V + peak AC: 5000 V RMS Common mode range: 7000 V + peak AC:2500 V RMS Input impedance: 10 MŁ/10 pF each side to ground Power requirements: 4 x AA cells (supplied) Safety rating: CAT I |
|
 |
|
 |
 |
|
ACTIVE DIFFERENTIAL PROBE 60 V, 200 MHzThe TA045 is a CAT I rated differential oscilloscope probe that can measure up to ±20 volts.
|  |
|
 |
|
ACTIVE DIFF PROBE SPECIFICATIONBandwidth: 200 MHz Attenuation: 10:1 Common mode: ±60 V Differential: ±20 V Input impedance: 500 kŁ / 7 pF Battery power: Optional (TA047) Safety rating: CAT I |
|
 |
|
 |
 |
|
TETRIS 1000 AND 1500 HIGH-IMPEDANCE ACTIVE PROBESThe TETRIS active probes can contact adjacent square pins in 2.54 mm pitch simultaneously. The probes housing is T-shaped so that many probes can be positioned next to each other in a continuous chain. This allows a number of measurements to be taken at the same time.
|  |
|
 |
|
TETRIS PROBE SPECIFICATIONAttenuation 10:1 Input impedance 1 MÙ Input capacitance 0.9 pF Working voltage 20 V Cable length 1.3 m
TETRIS 1000: Bandwidth 1 GHz
TETRIS 1500: Bandwidth 1.5 GHz |
|
 |
|
 |
 |
|
 |
 |
|
ACTIVE DIFFERENTIAL PROBE 1000 V OR 1400 V CAT IIIThe probe permits a conventional earthed oscilloscope to measure signals that are not referenced to earth, enabling mains voltages to be tested. Ideal for investigation of motor speed controls, uninterruptible power supplies, switch mode power supplies and process controllers. |  |
|
 |
|
TA041 SPECIFICATION Attenuation ranges: Bandwidth: Differential voltage range: ±70 V or 70 V RMS ±700 V or 700 V RMS Common mode voltage range: Input impedance: 4 MŁ / 5.5 pF Safety rating: |
|
 |
|
 |
 |
|
 |
 |
|
ACTIVE DIFFERENTIAL PROBE 15 V, 800 MHz, X1/10, CAT IIIThe TA046 is a high-bandwidth differential probe. It is ideal for measuring high-speed differential signals. |  |
|
 |
|
TA046 SPECIFICATIONAttenuation 10:1 Bandwidth 800 MHz Common mode ±30 V Differential ±15 V Input impedance 100 kÙ / 2 pF |
|
 |
|
 |
 |
|
ACTIVE DIFFERENTIAL PROBE 70 V, 50 MHz, x1/10, CAT IThe TA058 is a CAT I rated differential oscilloscope probe that can measure up to ±70 volts. |  |
|
 |
|
TA058 SPECIFICATIONAttenuation 10:1 Bandwidth 50 MHz Common mode ±700 V Differential ±70 V Battery power Optional (TA047) Input impedance 1.6 MÙ / 7 pF Safety rating CAT I |
|
 |
|
 |
 |
|
ACCESSORIES FOR ACTIVE PROBESThe TA047 is an optional 4AA battery pack for the TA045 and TA046 active differential probes. We also offer power supplies should you need to buy a new one. The PS008 is a 9 V power supply for all TA differential probes. The PS009 is a 15 V power supply for the TA046 only. |
|
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
3D PROBE POSITIONERThis 3D probe positioner is for scope probes and other measuring devices. This allows for hands-free testing and measuring, with accurate and safe positioning. It offers a stepless 3D clamping system. Available with fixed probe holder (MS100) or adjustable clamp (MSU1500). |  |
|
 |
|
 |
 |
|
 |
 |