The 4 channel EL041 thermocouple converter is designed to measure a wide range of temperatures with any thermocouple that uses a miniature size thermocouple connector.
Featuring built-in cold junction compensation (CJC), the EL041 has an effective temperature range of -270 to 1820°C (The actual temperature range depends on the thermocouple being used.)
In addition to temperature measurement, the cold junction compensation can be switched off to enable the EL041 to measure ±60mV signals.
Note: The EL041 is designed to work only with the EL005 logger.
| EL041 Thermocouple Specifications |
|---|
| Number of Channels | 4 | | Thermocouples Supported | B, E, J, K, N, R, S, T or mV | Voltage Input Range | +/-60 mV | Accuracy | Thermocouples: ±(0.5 °C + 0.3% of type K reading) Millivolts: ±0.3% | Conversion Time | 1 second | Overload Protection | +/-10V | Input Connector | Mini-thermocouple plugs | PC Connector | via EnviroMon network | Operating Temperature | 0 to 70 °C (20 to 30 °C for quoted accuracy | Operating Humidity | 25 to 75%RH |
|